Vietnamese-VNEnglish (United Kingdom)
Print PDF

VIC_ Vietnam Standard TCVN 7364-3 for laminated glass

 

 

1. Impact resistance

Unidentified impact resistance for laminated glass.

2. Durability of laminated glass and laminated thermo-resistant glass

2.1. High temperature resistant

Conducting the test method mentioned in Article 4 of TCVN 7364-4: 2004 and assess as 4.4 of TCVN 7364-4: 2004, on three samples there are not the defects (bubbles, blistering, spot). If on one of the three samples there are the defects, you have to test again on three new models, in this case there is not defective in any sample.

2.2. Moisture resistant

Conducting the test method described in Article 5.3.1 of the TCVN 7364-4: 2004 and assess as 5.4 of TCVN 7364-4: 2004, on three samples three are noy the defects (bubbles, blistering, marks etc). If on one of the three samples there are the defects, you have to test again on three new models, in this case there is not defective in any sample.

2.3. Radiation resistant

After trying the method described in Article 6 of the TCVN 7364-4: 2004 and assess as 6.5 of TCVN 7364-4: 2004, light transmission of all three illuminated patterns shall not exceed ± 10% difference compared to value of three samples before illumination for the initial light transmission> 20% or ± 2% absolute value for the initial light transmission £ 20%. When external evaluating  on three samples with no defects (bubbles, blistering, cracks, etc).

If one of the three samples is not satisfied, the test must be conducted on three new models, and all three samples must be pass over.

3. Reliability of laminated thermo-resistant glass

3.1. Group A

Group A glass is not directed solar radiation, often used in homes.

3.1.1. Moisture resistant reliabilaty

In conducting the test method described in 5.3.2 of TCVN 7364-4: -2004 and assess by 5.4 of TCVN 7364-4: 2004, there are not the blistering on the three samples. If a blistering seen in three modals then try to test three new models, and all three samples must pass.

3.2. Group B

Glass group B is directed solar radiation, often used outdoors.

3.2.1. Moisture resistant Reliabilaty

Conducting the test method described in 5.3.1 of TCVN 7364-4: 2004 and assess as 5.4 of TCVN 7364-4: 2004, there are not the blistering on the three samples. If a blistering seen in three partterns then try to test on three new models, and all three samples must pass.

3.2.2. Radiation durability

After trying the method described in Article 6 of the TCVN 7364-4: 2004 and assess as 6.5 of TCVN 7364-4: 2004, light transmission of all three forms of radiation are not exceed ± 10% compared to value of three samples before illumination for the initial light transmission> 20% or ± 2% absolute value for the initial light transmission £ 20%. When external evaluating on three samples with no defects (bubbles, blistering, cracks, etc).

If one of the three samples is not satisfied, the test must be conducted on three new models, and all three samples must pass.

4. Composition materials

The composition materials of the laminated glass outlined in TCVN 7364-1: 2004.

5. Dimensions and edge finishing

The perfect size and the edges of the laminated glass are specified in TCVN 7364-5: 2004.

6. Appearance

Appearance requirements outlined in TCVN 7364-5: 2004.

7. The symbol

Multi-layer laminated suitable with  this Standard denoted with the following information:

- Name of the glass;

- The standard notation;

- Nominal thickness, mm;

- Nominal width B and length H, mm.

For example, the sign for thermo laminated glass thick 6.4 mm, wide 2.0 m long, 1.50 m:

Thermo-resistant laminated glass TCVN 7364-3: 2004 -  6.4 -2000 x 1500.

| + - | RTL - LTR

Business Support

Business support 1
Business support 2
Business support 3

Technical Support

Technical Support 1
Technical Support 2
Technical Support 3

Contact Information

  • VIC INTERNATIONAL INVESTMENT & CONSTRUCTION MATERIAL TECHNOLOGY.,JSC (VIC.,JSC)
  • Add: 9th Floor, Bao Anh Building, 62 Tran Thai Tong Str, Cau Giay Dist, Ha Noi, Viet Nam
  • Tel: +84 43 7679 387 / +84 43 7679 388; Fax: +84 43 7679 389
  • Hotline: +84 904 61 6006
  • Email: info@viccons.com
  • Website: www.viccons.com / www.viccons.com.vn / www.nhomkinhkientruc.net